Abstract
Twenty-five patients who underwent bilateral lower extremity CTAs using standard lower extremity protocol were retrospectively identified. Axial two-dimensional images were scanned craniocaudally using our institution's standard CT image viewing software, Merge Radsuite (Merge Healthcare, Hartland, Wis.). The average location of distal-most PB perforators identified on CT angiogram was 13.1 ± 5.1 cm proximal to the distal fibula, or 34.5% ± 13.5% of total fibular length. Standard CTA was only able to locate a pedicle within 8 cm of the lateral malleolus (20.9% of fibular length) in three of 25 patients (12%). Previous studies have described a reliable pedicle within 8 cm of the distal fibular tip upon which to design a distally based PB rotational flap. The absence of such perforators in the CT angiogram suggests that standard CT angiogram is not a reliable technique for identifying the patency of such perforators when evaluating the utility of a distally based PB flap.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.