Abstract
Evaluation of donor lung function relies on the arterial oxygen partial pressure to inspired oxygen fraction ratio (PaO2 /FiO2 ) measurement. Hemodynamic, metabolic derangements, and therapeutic intervention occurring during brain dead observation may influence the evaluation of gas exchange. We performed a mathematical analysis to explore the influence of the extrapulmonary determinants on the interpretation of PaO2 /FiO2 in the brain-dead donor and during Ex-Vivo Lung Perfusion (EVLP). High FiO2 and increased mixed venous oxygen saturation, caused by increased delivery and reduced consumption of oxygen, raise the PaO2 /FiO2 despite substantial intrapulmonary shunt. Anemia does not modify the PaO2 /FiO2 -intrapulmonary shunt relationship. During EVLP, the reduced artero-venous difference in oxygen content increases the PaO2 /FiO2 without this corresponding to an optimal graft function, while the reduced perfusate oxygen-carrying capacity linearizes the PaO2 /FiO2 -intrapulmonary shunt relationship. Adopting PaO2 /FiO2 to evaluate graft suitability for transplantation should account for extrapulmonary factors affecting its interpretation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.