Abstract

We report two neonatal patients with high-flow intracranial or cervical arteriovenous (AV) shunts who presented with congestive heart failure and were successfully managed with endovascular treatment. One with vein of Galen malformation with body weight of only 2.0 kg is, to our knowledge, the smallest neonate successfully treated with endovascular treatment. The other neonate is, to our knowledge, the first vertebro-vertebral fistula patient presenting with heart failure and treated successfully with endovascular treatment. Even in neonates, endovascular treatment is the procedure of choice for high-flow AV shunts presenting with progressive congestive heart failure resistant to medical management. We discuss limitations and technical considerations of endovascular treatments in small neonates with high-flow AV shunts and congestive heart failure.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.