Abstract

This paper presents a new formula to estimate the ultimate lateral force of unreinforced masonry structures. The ratio of the wall's height to the wall's width is used to predict the ultimate lateral load of the wall. The coefficient is determined by the numerical implementation of an interface model to simulate the behavior of mortar joints in masonry walls. The numerical predictions are compared with the FEMA guidelines and the experimental data. The comparisons show that the loads that are predicted by the proposed formula have a lower error percentage than the FEMA guidelines. Thus, the proposed formula can be used to analyze unreinforced masonry structures.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.