Abstract

Limestone calcination is an important part of calcium looping (CaL) technology and is critical to the design and operation optimization of fluidized bed reactors. However, obtaining a method of measuring the fast calcination kinetics in a fluidizing environment with isothermal conditions is still a challenge in the field of calcium looping. We address this challenge in this work and develop a new method of obtaining limestone calcination kinetics by injecting limestone particles into the hot fluidizing sands in a microfluidized bed thermogravimetric analysis (MFB-TGA) with a mass measurement resolution of 1 mg. The calcination characteristics of limestone are investigated at different particle sizes (150–1250 μm), temperatures (750–920 °C), and CO2 concentrations (0–30 vol.%). The experimental data measured from MFB-TGA were analyzed using a detailed model including surface reaction and intraparticle and external diffusion. The results show that the kinetics of limestone calcination measured by MFB-TGA are faster than those measured via regular TGA. This particle-injecting method of MFB-TGA provides a new experimental idea for measuring fast calcination kinetics occurring inside fluidized bed reactors and provides guidance on the application of CaL technology.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call