Abstract

Industrial Wireless Sensor Networks (IWSNs) are nowadays becoming more and more popular thanks to their flexibility and pervasive monitoring capabilities to support process automation and remote maintenance applications. In such a scenario, channel errors due to the wireless medium can result in data packet losses, and consequently in unreliable IWSN services. To mitigate the above reported problem, this paper presents a lightweight error correction scheme specially developed for IEEE802.15.4-based IWSNs. By adding error correction and detection information inside the IEEE802.15.4 MAC data frame, the proposed FEC scheme is able to guarantee a backward compatibility with the standard while providing advanced capabilities in recovering data packets affected by bit errors. In the paper the benefits of the proposed technique are first evaluated through simulated loss traces, then they are validated in a real environment by considering real loss traces collected in an electricity power plant. The proposed error correction scheme is able to recover around 50% of the data packets that would be lost in case of a standard communication without any error correction capability.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.