Abstract

AbstractHigh‐speed video camera records, with a temporal resolution of 20 µs and a spatial resolution of 2.4 m per pixel, of a downward negative lightning flash that terminated on a 440 m high building are examined. The attachment process in this flash exhibited an unexpected behavior in that the downward leader tip connected to the lateral surface of the ~400 m upward connecting leader (UCL) below its tip. It appears that the effect of the downward leader on the UCL is significant, while the effect of the UCL on the downward leader is negligible, except for the final 80 µs preceding the beginning of the first return stroke. The ratio of speeds of the downward leader and the UCL tends to decrease with time, ranging from 1.8 to 0.12, although the lower 80–100 m or so of the UCL were too faint to allow speed measurements.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.