Abstract
Standard methods of testing the racking capacity of light‐frame walls are inefficient and may give erroneous estimates of shear wall performance. This study is concerned with improving the data base for racking resistance of light frame walls with plywood and gypsum sheathings. The shear resistance of small walls sheathed with gypsum was compared to that of full‐size walls. Results of both tests indicated that racking strength was linearly proportional to wall length. Contributions of sheathing layers and panel sections appear be additive, and length of wall sections containing door and window openings may be neglected in determining racking resistance of conventional walls. One notable difference in the performance of these racking tests involved the effect of panel length on racking stiffness. Stiffness of small walls increased linearly with length while the stiffness of full‐size walls increased nonlinearly. Knowledge that gypsum wallboard can contribute to shear wall performaoee and that it is additive to the resistance of plywood sheathing should be helpful to building designers and code officials.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.