Abstract

We can detect the beta-globin gene sickle cell mutation by using an assay based on the ligase chain reaction. The simultaneous amplification of the human growth hormone gene in the same reaction serves as a control for the amount of template DNA or amplification efficiency. Ligation products, which are biotinylated at one end and tagged with an arbitrary "tail" sequence at the other, are captured by hybridization to "tail"-complementary oligonucleotides immobilized on polystyrene microwells. The captured ligation products are detected colorimetrically by use of streptavidin-alkaline phosphatase conjugate. In a study of 24 subjects, the assay unequivocally discriminated among normal, carrier, and sickle cell genotypes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.