Abstract

In this work, electrocatalytic changes of Cu(II) triazole complexes (Cu(L)2) resulting from inductive effects were evaluated to fabricate a sensor for hydrogen peroxide (H2O2) determination. Three copper(II) complexes with electronically differentiated ligands were synthesized by slow diffusion method and characterized by X-ray crystallography, Fourier transformed infrared (FTIR), UV-Vis, scanning electron microscopy (SEM) and voltammetry cyclic (CV). Cu(LOMe)2/GC, Cu(LBr)2/GC and Cu(LNO2)2/GC sensors were then prepared. Under optimal conditions (pH = 11), the optimal sensor presented a response at -0.5 V, good linear range of 1-32 μM, reproducibility (1.7%), repeatability (1.2%), LOD of 0.0246 μM (S/N = 5), LOQ of 0.0747 μM (S/N = 5) and selectivity. Additionally, Cu(LNO2)2/GC sensor has been successfully applied in commercial substances, such as mouthwash, milk and tea.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call