Abstract
We investigate the effect of three testing conditions (thermal shock, Rapid Temperature Change – RTC – and high temperature storage) on the interconnects of a power electronic module. In particular, the mechanical strength of thick aluminium wirebonds is investigated and shows that while it is not affected by storage at 230°C, it is much more sensitive to thermal cycling. Shock tests are found to be especially severe, despite having a smaller temperature swing than RTC. Regarding the die attach, no noticeable reduction in mechanical strength is found, regardless of the ageing conditions, and despite clear micro-structural evolutions.
Submitted Version (Free)
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.