Abstract
PurposeThis paper aims to investigate the probability of unacceptable consequences from structural fire damage in a typical Scandinavian single-story steel frame building and discusses it in relation to life safety. This paper is a complement to the paper “Life safety in single-story steel frame buildings, Part I – deterministic design” by Sandström (2019) which considers the same design philosophy but with a probabilistic design approach.Design/methodology/approachThe reliability of a single-story steel frame building is investigated by using crude Monte Carlo simulation by including consideration to the fire conditions.FindingsThe investigated building does not meet the safety levels as stipulated by EN 1990 for structural fire damage. However, by including consideration to the fire conditions in the compartment, it is shown that the life safety objective is not compromised by the structural fire damage, i.e. the structure remains intact as long as any individuals/firefighters can survive within the fire area compartment.Originality/valueThis paper presents practical application of a conceptual paper presenting a general approach to structural fire safety design and the life safety objective.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.