Abstract

The comparative results of fatigue life assessment analyses are presented for piping branch connection of Tee type (Tee) of power station main steam piping. The results are derived using the German Standard TRD approach with and without usage of modified finite element analyses of transient thermal stresses, occurring during power station startup or shutdown. The traditional TRD approach for Tee stress analyses is conservative due to the use of formulas which are the upper estimate of transient thermal stresses. The TRD assumption about the coincidence of creep and fatigue maximum stress areas is very conservative as well. The analyses results enable us to extend the power station piping components life assessment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.