Abstract

The electrochemical and mechanical behaviour of 18,650 Li-ion cells subjected to abusive overcharge has been studied in constant current and constant voltage mode. The results from the cell deformation monitoring via a rectangular rosette strain gauges indicate an over-swelling process starting shortly after the cell voltage increases above 4.2 V. The acoustic ultrasound interrogation measurement and data treatment using clustering and mapping software, carried out in parallel, showed an abnormal evolution of the signals’ power density spectral patterns, suggesting changes in the structure of the cell jellyroll induced by the overcharge reactions. The increase in cell skin temperature due to the overcharge process starts considerably later. The results suggest that the monitoring of the mechanical behaviour of cylindrical-format Li-ion cells can be used for the detection and alerting of early overcharge safety events.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.