Abstract

This study validated a not yet commercially available fully-automated lexicographic optimization planning system (LOps) for single and multiple lesions intracranial stereotactic radiosurgery (SRS). Forty-four consecutive SRS treatment plans (21 Gy/1 fx) delivered between November 2019 and August 2022 were retrospectively selected and automatically re-planned by LOps: 25 of them has 1 lesion, 13 had 2 lesions, 4 had 3 lesions, and 2 had 4 lesions. An a-priori assigned priority list, Wish List (WL), was used to define the sequential LO: 4 patient sets (tuning set) were necessary to tune each WL, for single lesion-plans (SLp) and multiple lesion-plans (MLp). While in manual plans (MP), the arc setup is freely chosen, the WL was tuned to use 2 coplanar arcs of 140° and 360° for SLp and MLp, respectively. A 0° and 90° collimator rotation were set for counter-clockwise and clockwise arcs, respectively. The fluence optimization is followed by a Monte Carlo calculation (MCc) with 1 mm-dose grid and 0.5%-statistical uncertainty. A target coverage as high as possible was requested, with at least 80% of the prescription dose covering 99% of the PTV. The main criteria for SLp approval were a brain V12Gy <10 cm3. In MLp this criterion can be overcome to get the minimum target coverage. The remaining 36 SRS plans (21 SL and 15 MLp) were automatically re-planned (testing set). Testing plans were compared in terms of dose-volume constraints, conformality, and monitor units (MUs). Statistical significance was assessed by performing the Wilcoxon test and plan delivery accuracy was verified by pre-treatment QA. WLs-tuning took 3 days. Overall manual and automatic MCc time can be estimated at 8 hours and 3 hours, respectively. Statistically significant increases in SLp and MLp target coverage (GTV_D98%: +3.0% SL, +5.7% ML, PTV_D98%: +4.4% SL, +13.4% ML) and conformity index were registered. Automatic plans showed acceptably higher median brain V12Gy (SL: MP 7.2 cm3, SLp 7.6 cm3; ML: MP 8.7 cm3, MLp 10.3 cm3). The SLp registered a lower median MU number (-4.2%) while MLp were obtained with a higher median number of MU (+9.8%). This not statistically significant difference did not affect gamma passing rates. The novel LOps produced high-quality clinically acceptable SRS SL and ML plans with coplanar arcs according to institutional-specific planning protocols, significantly reducing the overall planning time from about one working day for one MP to about 3 hours for one automatic plan. Together with comparable OAR sparing, the target coverage was significantly increased and the plan deliverability preserved.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call