Abstract

Lewisite (2-chlorovinyldichloroarsine) is a chemical warfare agent developed during World War I. A quantitative method using solid phase extraction (SPE) followed by dual column liquid chromatography (LC)-isotope dilution tandem mass spectrometry(MS-MS) was developed for the determination of (2-chlorovinyl)arsonic acid (CVAOA), a metabolite of Lewisite, in human urine. The sample was treated with hydrogen peroxide to oxidize any (2-chlorovinyl)arsonous acid (CVAA) that remained in the trivalent arsenic oxidation state. There was 1.19% (arsenic purity) of bis-(2-chlorovinyl)arsinic acid (BCVAOA), a minor Lewisite metabolite, in the stock CVAA material. The high-throughput method qualitatively assessed BCVAOA simultaneously utilizing normal-phase silica SPE followed by reversed-phase C18 LC for an orthogonal separation. The chromatographic method results in a5.8-min cycle time with adequate retention (k'=2.4) of CVAOA. The mass spectrometer was operated in positive electrospray ionization mode with quantitativem/z 186.9→61.0 and confirmation 186.9→91.0 mass transitions. This selective method demonstrated linearity, accuracy and reproducibility for the clinically relevant calibration range (25-3,200 µg/L as CVAA). The method detection limit was 3.3 µg/L as CVAA from a 10µL injection. This LC-MS-MS emergency response method has a throughput of >240 samples(2.5 extracted 96-well plates) per day.