Abstract
This paper aims to determine the levels of exposure to neutron and photon radiation among the personnel engaged in cyclotron operation and the personnel engaged in the production of radiopharmaceuticals, with the use of the environmental radiation monitoring system (RMS) installed in the positron emission tomography laboratory. The annual exposures of employees operating the cyclotron measured with the use of the RMS system are: 1.39 ± 0.16 mSv in case of photon radiation and 2.61 ± 0.14 mSv in case of neutron radiation. In the case of employees in the radiopharmaceuticals’ production zone, the annual exposures measured by means of the RMS system are 0.15 ± 0.03 mSv in case of photon radiation and 0.11 ± 0.01 mSv in case of neutron radiation. The exposure levels among the personnel engaged in cyclotron operation and the personnel engaged in the production of radiopharmaceuticals are below the permissible radiation dose limits.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.