Abstract
This paper deals with the calculation of Levelized Electricity Cost (LEC) of five Solar Photovoltaic power (SPV) plants of different capacities 1MW, 5MW, 10MW, 25MW and 130MW. The calculation has been performed from the power generated data of the year 2014. The effect of different parameters like interest rate, inflation rate, deprecation time (plant life) and cumulative utilization factor (CUF), on LEC have been analyzed. A comparative study of the plants is done by varying these parameters. Operation and maintenance cost has been assumed 1% of the capital cost. It has been observed that LEC increases with increase in both inflation rate and interest rate. However, the influence of inflation rate on LEC is more. LEC decreases with increase in plant life and cumulative utilization factor. SPV plants established earlier have higher LEC compared to that of plants established later due to reduction in cost of SPV module prices over the years.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.