Abstract
To the Editor.— InThe Journal(225:524, 1973), an accident caused by impaction of a suction catheter an endotracheal tube was reported. The catheter had become disconnected from its adapter during suctioning, while the thorax was open and the patient the left lateral position. When attempts to remove the catheter with clamps failed, extubation and reintubation with a new tube were performed. This, as the author states was a hazardous procedure since the patient was in the lateral position... obscured by drapes and his chest... open. Indeed, under the described conditions, intubation may be impossible and emergency tracheostomy too late. A faster and safer method is to slowly withdraw the endotracheal tube (with its impacted catheter) and then to cut 1.27-cm sections of the endotracheal tube until the catheter becomes visible. At this time, the catheter is grabbed and pulled back for 5.08 cm. A new endotracheal tube
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.