Abstract

IntroductionData on catheter ablation of ventricular arrhythmias (VA) are scarce in patients with left ventricular assist devices (LVADs) and current evidence predominantly consists of case reports with outdated LVAD. This prospective observational study reports our experience in terms of catheter ablation of VAs in patients with novel 3rd generation LVADs.Methods and resultsBetween 2018 and 2020, nine consecutive patients undergoing a total number of ten ablation procedures for VAs were analyzed. The mean duration between LVAD implantation and catheter ablation was 23 ± 16 months. Acute procedural success was achieved in all patients. VA substrates were not related to the LVAD scarring (cannula) site in the majority of patients. All procedures were conducted without any relevant procedure-related complications. In terms of follow-up, only one patient presented with a repeat episode of electrical storm requiring ICD-shocks 16 months after the initial ablation procedure. Four patients suffered of singular VA effectively treated with antitachycardia pacing via their ICD. The remainder were free of any VA relapse (n = 4). Two non-procedure-related deaths occurred during follow-up.ConclusionsCatheter ablation of VAs in patients with 3rd generation LVAD is feasible and leads to satisfying clinical results in terms of freedom from VA recurrence and quality of life. The majority of arrhythmia substrates in these patients are not directly related to the LVAD cannulation site and may represent a progress of heart failure.Graphic abstract

Highlights

  • Data on catheter ablation of ventricular arrhythmias (VA) are scarce in patients with left ventricular assist devices (LVADs) and current evidence predominantly consists of case reports with outdated LVAD

  • The mean age was at the time of ablation was 60 ± 8 years, latency of LVAD implantation was a mean of 23 ± 16 months prior to VA ablation

  • The LVAD was implanted with the bridge-to-transplant (BTT) indication and as destination therapy (DT) in four cases

Read more

Summary

Introduction

Data on catheter ablation of ventricular arrhythmias (VA) are scarce in patients with left ventricular assist devices (LVADs) and current evidence predominantly consists of case reports with outdated LVAD. This prospective observational study reports our experience in terms of catheter ablation of VAs in patients with novel ­3rd generation LVADs. Methods and results Between 2018 and 2020, nine consecutive patients undergoing a total number of ten ablation procedures for VAs were analyzed. The majority of such patients is implanted with a third generation LVAD with technical reliability and sustained therapy results [2]. These novel devices are small intrapericardially implantable centrifugal-flow pumps [2, 3].

Methods
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.