Abstract

Background context Current surgical trends increasingly emphasize the minimization of surgical exposure and tissue morbidity. Previous research questioned the ability of unilateral pedicle screw instrumentation to adequately stabilize posterior fusion constructs. No study to date has addressed the effects of reduced posterior instrumentation mass on interbody construct techniques. Unilateral surgical exposure for transforaminal lumbar interbody fusion (TLIF) allows ipsilateral pedicle screw placement. Theoretically, percutanous contralateral facet screw placement could provide supplemental construct support without additional surgical exposure. Purpose Identify the biomechanical effects of reduced spinal fusion instrumentation mass on interbody construct stability. Study design An in vitro biomechanical study using human lumbar spines comparing stability of TLIF constructs augmented by: (1) bilateral pedicle screw fixation, (2) unilateral pedicle screw fixation, or (3) a novel unilateral pedicle screw fixation supplemented with contralateral facet screw construct. Methods Seven fresh frozen human cadaveric specimens were tested in random construct order in flexion/extension, lateral bending, and axial rotation using ±5.0 Nm torques and 50 N axial compressive loads. Analysis of torque rotation curves determined construct stability. Using paired statistical methods, comparison of construct stiffness and total range of motion within each specimen were performed using the Wilcoxon signed ranks test with a Holm-Sidák multiple comparison procedure (α = 0.05). Results In flexion/extension, lateral bending, and axial rotation, there were no measurable differences in either stiffness or range of motion between the standard bilateral pedicle screw and the novel construct after TLIF. After TLIF, the unilateral pedicle screw construct provided only half of the improvement in stiffness compared with bilateral or novel constructs and allows for significant off-axis rotational motions, which could be detrimental to stability and the promotion for fusion. Conclusions All tested TLIF constructs with posterior instrumentation decreased segmental range of motion and increased segmental stiffness. While placing unilateral posterior instrumentation decreases overall implant bulk and dissection, it allows for signficantly increased segmental range of motion, less stiffness, and produces off-axis movement. The technique of contralateral facet screw placement provides the surgical advantages of unilateral pedicle screw placement with stability comparable to TLIF with bilateral pedicle screws.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.