Heat transfer coefficients on a flat plate surface downstream a row of simple and compound angle cylindrical holes are investigated using high-resolution thermographic liquid crystal technique. A variation of flow parameters including blowing ratio, and geometry parameters including compound angle and length-to-diameter ratio are examined. Blowing ratios (M) ranging from 0.3 to 2, length to diameter ratios (L/D) from 0.5 to 5, and two compound angle (β: 0°, 45°) are employed composing a test matrix of 70 test cases. Detailed local, spanwise averaged, and area averaged heat transfer coefficients hf/h0 are presented to illustrate the effect of length-to-diameter ratio and compound angle. The film cooling performance is also evaluated using NHFR method and Δφ method by combining adiabatic film effectiveness and heat transfer coefficient data. Results indicate that Δφ method has superiority in evaluating film cooling performance due to its direct reflection of temperature reduction by film protection.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.