Abstract
Legionellae are environmental bacteria that can be frequently isolated from technical water supply systems. The most prevalent species is Legionella pneumophila, especially serogroup 1. In the environment, legionellae multiply in amoebae. Since Legionella pneumonias cannot be distinguished from pneumonias caused by other microbial pathogens, special microbiological tests, e.g., urinary antigen assays, are essential to detect Legionella infections. All water supply systems to which the patient is exposed during the incubation time of 2 to 10 days might be the source of the infection. This can be confirmed or excluded by molecular typing of isolates from patients and the environment. The most commonly used techniques are monoclonal antibody typing and sequence-based typing (SBT). Some sequence types (ST) are frequently found among clinical strains but are seldom isolated from the environment, e.g., ST 23, 42, 47, 62, and 146. It is safe to assume that such strains are highly virulent. Conversely, it does not seem to be justified to dedicate the same awareness to all environmental Legionella strains.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Bundesgesundheitsblatt - Gesundheitsforschung - Gesundheitsschutz
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.