Abstract

The aim of this study was to evaluate the left ventricular (LV) functional parameters calculated using quantitative electrocardiography (ECG)-gated myocardial perfusion single photon emission computed tomography (QGS). In addition to LV systolic parameters, diastolic parameters were compared with those by ultrasound echocardiography (UCG) and also with plasma B-type natriuretic peptide (BNP) concentrations. We examined 46 patients with various forms of heart disease. By the QGS data with 16 framing data acquisition using technetium (Tc)-99m methoxyisobutylisonitrile (MIBI) perfusion, we calculated the following parameters: LV end-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF), peak filling rate (PFR), filling rate during the first third of the filling time (1/3FR) and first third filling fraction (1/3FF). By UCG, we measured mitral early to atrial (E/A) wave velocity ratio and pulmonary venous inflow systolic/diastolic (S/D) ratio as diastolic functional parameters. Plasma BNP concentrations were also measured. There was a significant correlation between LVEDV, ESV and EF measured by QGS and UCG (EDV, r = 0.71, p < 0.001; ESV, r = 0.82, p < 0.001; EF, r = 0.75, p < 0.001). The PFR, 1/3FR and 1/3FF obtained by QGS correlated positively with E/A ratio (PFR, r = 0.54, p < 0.001; 1/3FR, r = 0.61, p < 0.001; 1/3FF, r = 0.42, p < 0.01) and negatively with S/D ratio (PFR, r = -0.40, p < 0.01; 1/3FR, r = -0.38, p < 0.05; 1/3FF, r = -0.39, p < 0.01) obtained by UCG. Plasma BNP concentrations in EF < 50% patients were greater than those in EF > or = 50% patients (335.2 +/- 60.2 vs. 101.2 +/- 41.3 pg/ml, p < 0.01, both n = 17). Plasma BNP levels were also compared between higher and lower 1/3FF patients matched for LVEF. Plasma BNP concentrations in 1/3FF < 35% patients were significantly greater than those in 1/3FF > or = 35% patients (312.9 +/- 62.5 vs. 120.5 +/- 32.8 pg/ml, p < 0.05, both n = 14). The degree of LV systolic and diastolic dysfunctions evaluated by QGS correlated with that by UCG or BNP. The QGS functional parameters offer useful information regarding cardiac failure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.