Abstract

This study aimed to develop a measure of longitudinal, radial, and circumferential myocardial strain at rest and regadenoson during pharmacologic stress using 82Rb PET electrocardiography-gated myocardial perfusion imaging (MPI). Methods: We retrospectively identified 80 patients who underwent rest and regadenoson-stress CT attenuation-corrected 82Rb PET and had a standard resting transthoracic echocardiogram (TTE) with global longitudinal strain (GLS) analysis within 3 mo. A method was developed to compute longitudinal, radial, and circumferential strain from PET MPI at stress and rest. PET MPI-derived strain and left ventricular function were compared with resting TTE measures as the clinical reference standard. Interobserver agreement of PET MPI strain and left ventricular ejection fraction processing was reported. Results: Longitudinal strain assessed with resting TTE GLS showed good correlation with PET MPI at stress (r = 0.68, P < 0.001) and rest (r = 0.58, P < 0.001). Resting TTE GLS also correlated with PET MPI radial strain at stress (r = -0.70, P < 0.001) and rest (r = -0.59, P < 0.001) and circumferential strain at stress (r = 0.67, P < 0.001) and rest (r = 0.69, P < 0.001). The left ventricular ejection fraction showed good correlation between resting TTE and PET MPI at stress (r = 0.83, P < 0.001) and rest (r = 0.80, P < 0.001). Bland-Altman analysis indicated positive bias of TTE GLS compared with PET MPI longitudinal strain at stress (mean difference = 5.1%, 95% CI = [-2.5, 12.7]) and rest (mean difference = 4.2%, 95% CI = [-4.3, 12.8]). Reproducibility of PET MPI longitudinal strain showed good agreement at stress (concordance correlation coefficient = 0.73, P < 0.001) and rest (concordance correlation coefficient = 0.74, P < 0.001), with Bland-Altman analysis showing a small bias in the longitudinal direction at stress (mean difference = -0.2%) and rest (mean difference = -1.0%). Conclusion: Strain measured with PET MPI using an automated technique correlated well with resting GLS strain obtained by TTE, and the measure is reproducible. Strain from PET MPI should be investigated further to establish reference ranges and assess its value in routine clinical practice.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.