Abstract

The left ventricular performance in patients with pulmonary atresia with intact ventricular septum who were Fontan candidates before and after the bidirectional Glenn procedure and a staged total cavopulmonary connection was compared with that in patients with tricuspid atresia. Contractility (end-systolic elastance), afterload (effective arterial elastance), and ventricular efficiency (ventriculoarterial coupling, arterial elastance/end-systolic elastance ratio), and the ratio of stroke work and pressure-volume area were approximated on the basis of cardiac catheterization data before the bidirectional Glenn procedure, before and after staged total cavopulmonary connection, and approximately 1 year after the completion of total cavopulmonary connection in 20 patients with pulmonary atresia with intact ventricular septum and 21 patients with tricuspid atresia. The end-systolic elastance of the pulmonary atresia with intact ventricular septum group was significantly inferior to that of the tricuspid atresia group after bidirectional Glenn procedure and total cavopulmonary connection (1 year after total cavopulmonary connection 1.85 +/- 0.51 mm Hg . m 2 . mL -1 vs 2.84 +/- 0.96 mm Hg . m 2 . mL -1 , P < .01). The arterial elastance was not different between groups throughout the assessment period and tended to increase in a stepwise fashion after bidirectional Glenn procedure and total cavopulmonary connection. The arterial elastance/end-systolic elastance ratio and ratio of stroke work and pressure-volume area of the pulmonary atresia with intact ventricular septum group tended to worsen, whereas those of the tricuspid atresia group tended to improve. The difference reached statistical significance 1 year after total cavopulmonary connection (1.15 +/- 0.35 vs 0.82 +/- 0.23 and 64.2% +/- 6.7% vs 71.3% +/- 5.7%, respectively, P < .05 and P < .05, respectively). The contractility and ventricular efficiency of patients with pulmonary atresia with intact ventricular septum are inferior to those of patients with tricuspid atresia after bidirectional Glenn procedure and total cavopulmonary connection. A high-pressure residual right ventricle may impair the left ventricular performance of patients with pulmonary atresia with intact ventricular septum after bidirectional Glenn procedure and total cavopulmonary connection.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.