Abstract
A 71-year-old man with class IV congestive heart failure and an infected pacemaker/implantable cardioverter defibrillator (ICD) underwent median sternotomy for removal of endocardial leads with a 15-mm vegetation. Cardiac output during biventricular pacing was optimized with an aortic flow probe, a multi-electrode left ventricular patch, and a randomized protocol assessing 54 combinations of pacing site and right ventricle-left ventricle delay. Results that were assessed with response surface methodology determined permanent epicardial lead position and timing. The difference between the best and worst site-timing combinations altered cardiac index by nearly 70%. This experience demonstrates potential importance of the epicardial approach to site-timing optimization for biventricular pacing.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.