Abstract

Multigated radionuclide angiography was performed at rest and during atrial pacing in 10 normal subjects. Left ventricular volumes in diastole and systole were measured by total counts in the region of interest of the left ventricle. Stroke volume, cardiac output, ejection fraction, and rates of ejection for each heart rate were calculated. As heart rate increased, there was a gradual decrease in end-diastolic, end-systolic, and stroke volumes without a significant change in cardiac output and ejection fraction. Ejection fraction rate increased and the uncorrected ejection rate decreased with the increase in heart rate. The normal response to tachycardia induced by atrial pacing was a decrease in ventricular volumes without a change in ejection fraction or cardiac output.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.