Abstract
ObjectivesTo analyze the acute and short-term deformation changes of both right (RV) and left (LV) ventricular wall before and after transcatheter closure of atrial septal defect (ASD) secundum in children.Outcome measuresTo determine the feasibility of tissue Doppler and myocardial deformation imaging for evaluating RV and LV functions in children undergoing transcatheter ASD closure.Patients and methodsA prospective study was performed for 32 children with hemodynamic significant ASD secundum before and 6 months after percutaneous ASD closure in the Pediatric Cardiology Division of Specialized Pediatric Hospital, Cairo University. Speckle tracking echocardiography (STE) of LV and RV global analysis (longitudinal and circumferential strain) before and after ASD transcatheter closure was performed.ResultsThe mean age of the patients was 6.01 ± 3.19 (range: 3–9) years with a female to male ratio of 1.3:1. There was an improvement in the RV and LV myocardial performance index (MPI) 6 months post-ASD closure (RVMPI = 0.46 ± 0.069 vs. 0.38 ± 0.05, p < 0.0001; LVMPI = 0.49 ± 0.12 vs. 0.38 ± 0.08, p < 0.0001, respectively). By 2D STE, there was a significant improvement in the RV global longitudinal strain (GLS) 6 months post-ASD closure (−20.17 ± 3.14% vs. −25.86 ± 5.02%, p < 0.0001). There was a significant increase in the LV end-diastolic volume (EDV) and LV end-systolic volume (ESV) using 4D STE after device closure (LVEDV = 32.96 ± 10.99 mL vs. 44.024 ± 14.9017 mL, p < 0.0001; LVESV = 15.16 ± 6.08 mL vs. 21.76 ± 8.34 mL, p < 0.0001, respectively). Additionally, there was a significant improvement in the LV GLS after device occlusion (−19.17 ± 3.67% vs. −22.36 ± 4.72%, p = 0.009) using 4D TomTec software. There was a significant decrease in the RVEDV (54.65 ± 10.05 mL vs. 15.73 ± 8.67 mL) and RV stroke volume (25.15 ± 6.36 vs. 20.06 ± 7.2) after device occlusion using 4D TomTec software.ConclusionBy using 4D STE, the LV GLS was significantly improved; in contrast, by 2D STE, the RV volume overload decreased and the RV GLS was improved on short term after transcatheter ASD secundum closure in children.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.