Abstract

The behavior of an electrified liquid jet breakup and modes of disintegration were investigated at different flow rates and voltages. The current phenomenology belongs to a new injector introduced recently by Morad et al. (2016). This injector has proven to highly extend the stability and flow rate of electrospray particularly in the Taylor cone-jet mode. The experimental investigation was performed using a high-power light-emitting diode (LED) illumination as the light source. The light source was developed to operate in the pulsing condition when synchronized with a digital camera and was particularly designed to function properly in the presence of high electromagnetic interference (EMI). The details of the light source development were observed through the images captured from the jet breakup at different modes. Finally, the operational map of the new injector was obtained, and the physical mechanisms of different behaviors were examined.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.