Purpose: To evaluate blue light hazards of LED lightings in an optical store with blue light radiance used as the quantitative indicators of photobiological hazard. Methods: The spectral radiance of each LED lightings was measured, and blue-light radiance and the corresponding maximum exposure time were calculated. Then each LED lighting was classified according to the risk group from IEC 62471 standard. Results: The yellow LED lightings used in showcases and white LED lightings used on ceilings and logo were classified into risk group RG0. But the white LED lightings used on showcases were classified into risk group RG1. The blue light radiances of white LED lightings used in showcases are dozens of times larger than that of fluorescent lamp. Conclusions: Using the value of the blue light radiance could quantitatively express the blue light hazard to various lightings. It was confirmed that white LED lightings for the showcases had high blue light hazards because of their high luminance and color temperature. Therefore, when replacing lightings in optical shop it is necessary to select the appropriate brightness and color temperature for eye health in the long term.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.