Abstract

To define the learning curve of a widely employed stent-graft for thoracic endovascular repair (TEVAR) by analyzing procedural variables and their impact on long-term outcomes. Standard TEVARs for each major aortic thoracic disease were included excluding procedures using thoracoabdominal, arch fenestrated/branched devices and/or chimneys. The primary outcome was the learning curve analysis using the cumulative sum chart method. The secondary outcomes, presented as early (Q1-Q2) versus latest (Q3-Q4) quartiles of experience, were 30-day major adverse events (MAEs); procedural details (additional maneuvers, operative and fluoroscopy time, and contrast volume); 30-day clinical success; endoleak; aorta-related reintervention; and overall and aorta-related survival. Between November 2005 and September 2021, 220 consecutive TEVAR procedures involving the Relay endograft (Terumo Aortic, Sunrise, FL, USA) were performed and included in the present analysis. The mean follow-up was 4.5 ± 3.9 years. The learning curve was reached after 10 patients. Secondary outcomes improved significantly over experience. Thirty-day MAE occurrence was 14.5% versus 11.8% (p=0.550). Additional maneuvers (p=0.009), access-vessel additional maneuvers (p=0.010), operative time (p=0.004), Relay Plus (p=0.001), and implantation of multiple stent-grafts (p=0.034) were independent risk markers for MAEs. Operative time (125.9 ± 66.7 vs 86.7 ± 48.5 minutes, p<0.001), contrast volume (185.4 ± 112.8 vs 140.5 ± 88.2 mL, p=0.003), and fluoroscopy time (12.4 ± 12.7 vs 8.8 ± 7.5 minutes, p=0.017) decreased significantly. Late endoleak occurrence was 19.5% with a nonsignificant reduction (21.8% vs 17.3%, p=0.395). Fluoroscopy time (hazard ratio [HR]=1.0; 95% confidence interval [CI]=1.0-1.1; p=0.008), contrast volume (HR=1.0; 95% CI=1.0-1.1; p=0.018), and type III aortic arch (HR=3.3; 95% CI=1.7-6.4; p<0.001) were independent risk markers for endoleak. Fluoroscopy time (HR=1.0; 95% CI=1.0-1.1; p=0.032) and type III aortic arch (HR=3.6; 95% CI=1.7-7.4; p=0.001) confirmed their significant association in a multivariable analysis. In a high-volume center with a consistent previous endovascular experience, the Relay graft presented satisfactory long-term results with a short learning curve supporting its reliability. The manuscript addresses the understanding of how many TEVAR procedures with a currently implanted device have been required to reach the learning curve for an endovascular skilled center. Our TEVAR experience with the Relay stent-graft (Terumo Aortic) demonstrated that ten implantations were required to achieve the device-related learning curve. The fifteen-year analyzed period showed that intraoperative learning-related variables were associated with long-term clinical outcomes and both improved over time. The Relay stent-graft presented satisfactory long-term results along with a short learning curve in a high-volume endovascular center supporting its ongoing implantation.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call