Abstract
Following Hemker and Maas (1987) the models of two or three leaky aquifers are applied to simulate the flow to vertical wells operating in the fractured or dual porosity aquifers. The software WellTest (WT) (Székely 2015) is used for calculating the drawdown and discharge rate variation. The comparative analysis with the independent analytical solutions by Boulton and Streltsova-Adams (1978), Warren and Root (1963), Kazemi et al. (1969) concluded with acceptable agreement between the WT simulation and the alternate calculation methods. The selected field tests have been conducted in fractured limestone aquifers. The pumping test west of Copenhagen shows an example of fractured aquifer with considerable negative skin effect at the well face. The flowing well Wafra W1 in Kuwait operates in the two-zone aquifer exhibiting sufficient vertical recharge via leakage beyond a circular domain of estimated radius of 2460 m.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.