Abstract
Purpose: Lead containing dust may be present on the exterior surfaces of shields used to prevent radiation exposure. We determined whether use of lead shields poses an exposure risk for radiology personnel.Methods: We collected hand dustwipe and blood samples from 58 Radiology Department employees of an academic hospital. Samples were analyzed for lead content by atomic absorption spectroscopy. Results were compared between lead apron users (46) and nonusers (12).Results: Hand dustwipe lead was undetectable (<3 µg/sample) in all cases. Blood lead levels ranged from 0–3 µg/dL.Conclusions: In this study of Radiology Department workers, we did not find an increased risk of lead contamination on their hands or in their blood. Although our sample size is small, we conclude that lead poisoning is unlikely to occur with high frequency in lead shield users.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.