Abstract
A study focusing on the ability to utilize isotopic analysis of Pb used in small arms projectiles from varying geographic origin was undertaken using the GV Instruments Isoprobe multicollector inductively coupled plasma mass spectrometer. With the exception of two classes of ammunition, these samples were able to be distinguished from one another. Also, following rigorous normalization and mass bias correction, these data were compared to data collected by geochemists in localities corresponding to projectile manufacture. This comparison was successful when projectiles in certain economically isolated countries were analyzed. Pb isotopic analysis with MC−ICPMS is shown to be useful as a tool for distinguishing between ammunition of various manufacturing origins.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.