Abstract

BackgroundIngestion of flakes of Pb-based paint by infants remains a global health hazard with life-long consequences. Pb-based paint was banned for residential use in the US and Western Europe decades ago but is still sold in many countries. This study evaluates the performance of a new kit for detecting exposed Pb-based paint relying on the formation of Pb-halide perovskite that fluoresces bright green under a UV flashlight after spraying a non-toxic reagent. ResultsTests with the Lumetallix kit were conducted in parallel with X-fluorescence and inductively-coupled plasma atomic emission analysis upon acid digestion using paint currently sold in Côte d'Ivoire and samples of older US paint. Comparison of the three different methods indicates a detection limit for the Lumetallix kit of approximately 500 mg kg−1 (ppm) Pb in paint, with a sensitivity of 95 % and selectivity of 94 % relative to that threshold (n = 76). This detection limit is an order of magnitude below the US definition of Pb-based paint of 0.5 % (5,000 ppm) Pb by weight. SignificanceBecause the kit is easy to use, exposed paint posing a risk could reliably be screened at scale by the general public. Any follow-up for confirmation and mitigation based on XRF measurements will need to consider that Pb-based paint covered with low-Pb paint will not respond to the kit but will be detected by XRF through the overpainted layer.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call