Abstract

In the present study, the degradation behavior of Fenofibrate under different International Conference on Harmonization (ICH) suggested conditions was studied. Characterization of degradation products by liquid chromatography–tandem mass spectrometry (LC–MS/MS) studies in solution form was done, and the possible mechanism for the formation of degradants is discussed. Fenofibrate was subjected to different hydrolytic stress conditions and thermal stress condition (in solid form). Successful separation of drug from degradants was achieved on a C18 column using water–acetonitrile (25:75 v/v) as the mobile phase. Other high-performance liquid chromatography (HPLC) parameters were: flow rate, 1 mL min−1; detection wavelength, 286 nm; column temperature, 25 °C; and injection volume, 20 μL. The method was validated for linearity, precision, accuracy, robustness, and specificity and was stability-indicating one, based on the specificity studies. The drug degraded under acidic, basic, and oxidative hydrolytic stre...