Abstract

An isocratic reversed phase-liquid chromatographic (RP-LC) method has been developed for the determination and purity evaluation of rofecoxib in bulk and pharmaceutical dosage forms using photodiode array detection set at 225 nm. The method is simple, rapid and selective. The method is capable of detecting all process intermediates and other related compounds, which may be present at trace levels in finished products. Hence the method is very useful for process monitoring during the production of rofecoxib. Chlorophenyl methyl sulphone has been used as internal standard for the quantitative determination of rofecoxib. The method is linear in the range of 125-500 microg. The precision for inter- and intra-day assay variation of rofecoxib is below 1.6% relative standard deviation (R.S.D.). The accuracy determined as relative mean error (R.M.E.) for the intra-day assay is within +/-2.0%. The drug was extracted from tablets (Vioxx) using acetonitrile. The percentage recoveries from dosage forms were ranged from 98.2 to 102.6.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.