Abstract

A novel method, continuous-flow microextraction (CFME) combined with liquid chromatography (LC) with variable-wavelength detector (VWD), has been developed for the determination of three phthalate esters (dimethyl phthalate (DMP), diethyl phthalate (DEP), and di-n-butyl phthalate (DnBP)) in water samples. Experimental parameters including extraction solvent, solvent drop volume, flow rate of sample solution, extraction time and ionic strength, which affected the extraction efficiency, were studied and optimized. Under the optimum extraction conditions, the method yields a linear calibration curve in the concentration range of 10–10,000 ng mL -1 for target analytes. The enrichment factors of this method for DMP, DEP and DnBP reached at 27, 44 and 20, respectively, and the detection limits were 2, 1 and 5n g mL -1 , respectively. Good repeatability of extraction was obtained with relative standard deviations below 8.6%. The results demonstrated that CFME followed by LC-VWD is a simple and reliable technique for the determination of phthalate esters in water samples.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.