Abstract

A problem faced by all Monte Carlo (MC) particle transport codes is how to handle overlapping geometries. The Geant4 MC toolkit allows the user to create parallel geometries within a single application. In Geant4 the standard mass-containing geometry is defined in a simulation volume called the World Volume. Separate parallel geometries can be defined in parallel worlds, that is, alternate three dimensional simulation volumes that share the same coordinate system with the World Volume for geometrical event biasing, scoring of radiation interactions, and/or the creation of hits in detailed readout structures. Until recently, only one of those worlds could contain mass so these parallel worlds provided no solution to simplify a complex geometric overlay issue in brachytherapy, namely the overlap of radiation sources and applicators with a CT based patient geometry. The standard method to handle seed and applicator overlay in MC requires removing CT voxels whose boundaries would intersect sources, placing the sources into the resulting void and then backfilling the remaining space of the void with a relevant material. The backfilling process may degrade the accuracy of patient representation, and the geometrical complexity of the technique precludes using fast and memory-efficient coding techniques that have been developed for regular voxel geometries. The patient must be represented by the less memory and CPU-efficient Geant4 voxel placement technique, G4PVPlacement, rather than the more efficient G4NestedParameterization (G4NestedParam). We introduce for the first time a Geant4 feature developed to solve this issue: Layered Mass Geometry (LMG) whereby both the standard (CT based patient geometry) and the parallel world (seeds and applicators) may now have mass. For any area where mass is present in the parallel world, the parallel mass is used. Elsewhere, the mass of the standard world is used. With LMG the user no longer needs to remove patient CT voxels that would include for example seeds. The patient representation can be a regular voxel grid, conducive to G4NestedParam, and the patient CT derived materials remain exact, avoiding the inaccuracy of the backfilling technique. Post-implant dosimetry for one patient with 125I permanent seed implant was performed using Geant4 version 9.5.p01 using three different geometrical techniques. The first technique was the standard described above (G4PVPlacement). The second technique placed patient voxels as before, but placed seeds with LMG (G4PVPlacement+LMG). The third technique placed patient voxels through G4NestedParam and seeds through LMG (G4NestedParam+LMG). All the scenarios were calculated with 3 different image compression factors to manipulate the number of voxels. Additionally, the dosimetric impact of the backfilling technique was investigated for the case of calcifications in close proximity of sources. LMG eliminated the need for backfilling and simplified geometry description. Of the two LMG techniques, G4PVPlacement+LMG had no benefit to calculation time or memory use, actually increasing calculation time, but G4NestedParam+LMG reduced both calculation time and memory. The benefits of G4NestedParam+LMG over standard G4PVPlacement increased with increasing voxel numbers. For the case of calcifications in close proximity to sources, LMG not only increased efficiency but also yielded more accurate dose calculation than G4PVPlacement. G4NestedParam in combination with LMG present a new, efficient approach to simulate radiation sources that overlap patient geometry. Cases with brachytherapy applicators would constitute a direct extension of the method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.