Corrosion failures due to condensing flue gases containing H2O, SO3, NOx and HCl still occur more often than might be expected. The corrosion failures can be of several types: general corrosion, pitting attack and stress corrosion cracking (SCC). The chemistry of condensing gases is discussed, and some examples of corrosion in large‐scale installations are presented, including blast stoves for steel production, heat recovery steam generators, and waste incineration boilers. The use of thermal insulation inside boiler casings can result in nitrate SCC when the flue gas contains high concentrations of NOx. Nitric acid from flue gas can react with carbon steel and insulation material forming ammonium nitrate and calcium nitrate. Both materials have hygroscopic properties and are very corrosive, even above the water dewpoint of the gases.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.