Abstract

BackgroundThe extensile lateral approach (ELA) has been widely used to treat displaced intra-articular calcaneal fractures (DIACFs) and remains the gold standard procedure. Orthopedic surgeons are extremely concerned of the high rate of wound complications. This study intended to report a new surgical technique of the lateral wall osteotomy combined with an embedded biodegradable implant for treating DIACFs and assess clinical and radiological results.MethodsFrom May 2013 to December 2015, a total of 17 patients with 19 calcaneal fractures underwent surgical treatment using our new technique. Radiographic images, computed tomography (CT) scans, and magnetic resonance (MR) images of the operative limb were obtained to assess fracture healing and biodegradable implant degradation. American Orthopaedic Foot and Ankle Society (AOFAS) ankle/hindfoot score at the last follow-up was obtained to assess functional result for all cases. Böhler’s and Gissane’s angles, width, and height of the injured calcaneus were analyzed using preoperative and last follow-up radiographic images.ResultsAll radiological parameters were significantly improved at the last follow-up, with an increase of 15.58°, 8.38°, and 7.65 mm in Böhler’s angle, Gissane’s angle, and calcaneal height, respectively, and a decrease of 2.51 mm in calcaneal width (p < 0.05). Mean AOFAS score at the last follow-up was 84.37 ± 9.98, with 9, 6, and 4 feet, having excellent, good, and fair rates, respectively. None had nonunion, delayed union, or malunion after a mean follow-up of 34.69 ± 5.22 months. One superficial infection occurred 6 days post-surgery.ConclusionsOsteotomy of the lateral wall of the calcaneus allows tension-free suturing and avoids damage to penetrating branches of the lateral calcaneal artery (LCA). Biodegradable implants are easy to reshape and do not require surgical removal. However, they should be limited to Sander’s type II and III fractures only.Level of evidenceLevel IV, case series without controls

Highlights

  • The extensile lateral approach (ELA) has been widely used to treat displaced intra-articular calcaneal fractures (DIACFs) and remains the gold standard procedure

  • The extensile lateral approach (ELA) has been widely used to treat DIACFs and remains the gold standard procedure for calcaneal fracture surgery owing to its excellent

  • Achieving the ideal reduction and stable fixation of calcaneal fractured fragments is difficult in these procedures, thereby leading to poor clinical outcomes [4, 5]

Read more

Summary

Introduction

The extensile lateral approach (ELA) has been widely used to treat displaced intra-articular calcaneal fractures (DIACFs) and remains the gold standard procedure. This study intended to report a new surgical technique of the lateral wall osteotomy combined with an embedded biodegradable implant for treating DIACFs and assess clinical and radiological results. The extensile lateral approach (ELA) has been widely used to treat DIACFs and remains the gold standard procedure for calcaneal fracture surgery owing to its excellent. The impaired microvascularization of the posterior lateral skin flap that resulted from the initial or iatrogenic injury was considered the cause of numerous wound-healing complications, because the lateral calcaneal artery (LCA), derived from the posterior peroneal artery, is responsible for blood supply to the posterior lateral area of the foot. Fixation strength of biodegradable implants was described previously, and its safety and effects at different terms were confirmed [7,8,9]

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call