Bridge abutments typically contain a backwall element that is designed to break free of its base support when struck by a bridge deck during an earthquake event and push into the abutment backfill soils. Results are presented for a full-scale cyclic lateral load test of an abutment backwall configured to represent the dimensions ( 1.7 m height), boundary conditions, and backfill materials (compacted silty sand) that are typical of California bridge design practice. An innovative loading system was utilized that operates under displacement control and that assures horizontal wall displacement with minimal vertical displacement. The applied horizontal displacement ranged from null to approximately 11% of the wall height (0.11H) . The maximum earth pressure occurred at a wall displacement of 0.03H and corresponded to a passive earth pressure coefficient of Kp =16.3 . The measured force distribution applied to the wall from hydraulic actuators allowed the soil pressure distribution to be inferred as triangula...