This paper analyses the lateral load performance of a post-tensioned timber (Pres-Lam) frame which was designed with the primary function of supporting gravity loading. A full scale, two bay frame was used and subjected to quasi-static horizontal displacement. A total of four tests were performed, one with only the post-tensioning cables to resist horizontal loading and three with the addition of sacrificial steel elements externally attached and acting as dissipative reinforcing. This external reinforcing increased the moment capacity of the frame connections and the ability of the frame to release energy through hysteretic damping. Following a description of the test setup the results show that although the primary functions of the post-tensioning is to reduce section height and increase bay length under gravity loading it will also provide a significant contribution to the lateral resistance of the structure. Finally, a simplified design procedure is presented which allows assessing the magnitude of this contribution.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.