Abstract

AbstractThe experimental in-plane force-displacement response of unreinforced masonry (URM) walls with flanges (return walls) subjected to pseudo-static cyclic lateral loading is presented. Each wall failed in a diagonal tension mode followed by bed-joint sliding. The effect of wall flanges was an increase in the displacement capacity of the in-plane loaded wall, in comparison with an in-plane loaded wall without flanges. The measured shear strengths of the walls were compared with an analytical model for determining the limiting diagonal tension strength of the walls, with a high level of correlation. The initial stiffness of the shear walls before the effective yield was compared with the initial stiffness as determined using conventional principles of mechanics for homogeneous materials, and it was found that with some approximations the initial stiffness could be satisfactorily determined. Because the bed-joint sliding failure mechanism exhibited by the walls is a deformation-controlled action, there ...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.