Abstract

To describe a case series of cerclage failures due to cheese-wiring; iris repair can develop late cheese-wiring of cerclage sutures with resultant loss of benefits. Cincinnati Eye Institute, Cincinnati, Ohio. Retrospective single-surgeon case series. A retrospective chart review sought patients who underwent iris cerclage at the Cincinnati Eye Institute who later developed suture cheese-wiring. The patient symptoms, demographics, cerclage size, suture type, knot type, iris status, and suture status at final follow-up were ascertained. 6 cases of cerclage suture cheese-wiring with loss of the original surgical benefit were identified. 10-0 polypropylene suture and a 3-1-1 knot were used in each case. The suture remained intact with an intact knot and suture loop in all cases. Cheese-wiring with return of mydriasis is a potential long-term outcome of iris cerclage suture placement, with return of preoperative symptoms. Awareness of this potential eventuality provides physicians and patients a broader perspective when selecting between cerclage suture, iris prosthesis placement, or other surgical and nonsurgical options.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.