Abstract
We report the surgical case of a 25-year old man admitted because of progressive dyspnoea and stabbing chest pain, who had undergone a pectus excavatum correction using a retrosternal strut 8 years previously. The computerized tomography scan showed that the right tip of the pectus bar had migrated across his right ventricle and tricuspid valve into the right atrium. Intraoperatively, it was confirmed that in its path, the right coronary artery and the posterior leaflet of the tricuspid valve had been damaged. After removing the bar and repairing the tricuspid valve, the patient made a full recovery.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.