Abstract

The late complications of corneo-scleral wound healing after the 15th postoperative day were recorded in 108 routine adult cataract operations using 7-0 polyglycolic acid (Dexon) sutures and compared with 80 routine adult cataract operations using 9-0 monofilament nylon (9-10 Ethilon Nylon) sutures. In 37 eyes of the 7-0 Dexon group filtrating blebs, gaping of the corneoscleral wound, anterior chamber collapse, or decrease in the intraocular pressure were observed compared with one filtrating bleb in the 9-0 nylon group. The majority of late complications occurred 22 to 42 days after surgery. Ten filtrating blebs remained after a 5 months' follow-up period. The most probable cause of the late complications in corneo-scleral wound healing was discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.