Abstract

The dependence of retinal damage threshold on laser spot size was examined for two pulsewidth regimes; nanosecond- duration Q-switched pulses from a doubled Nd:YAG laser and microsecond-duration pulses from a flashlamp-pumped dye laser. Threshold determinations were conducted for nominal retinal image sizes ranging from 1.5 mrad to 100 mrad of visual field, corresponding to image diameters of approximately 22 μm to 1.4 mm on the primate retina. In addition, baseline collimated-beam damage thresholds were determined for comparison to the extended source data. Together, this set of retinal damage thresholds reveals the functional dependence of threshold on spot size. The threshold dose was found to vary with the area of the image for larger image sizes. The results are compared to previously published extended source damage thresholds and to the ANSI Z136.1 laser safety standard maximum permissible exposure levels for diffuse reflections.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.