Abstract

The exposure and emission limits of ICNIRP, IEC 60825-1 and ANSI Z136.1 to protect the cornea are based on a limited number of in-vivo studies. To broaden the database, a computer model was developed to predict injury thresholds in the wavelength range from 1050 nm to 10.6 µm and was validated by comparison with all applicable experimental threshold data (ED50) with exposure duration between 1.7 ns and 100 s. The model predictions compare favorably with the in-vivo data with an average ratio of computer prediction to ED50 of 0.94 (standard deviation ± 30%) and a maximum deviation of less than 2. This computer model can be used to improve exposure limits or for a quantitative risk analysis of a given exposure of the cornea.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.